Affordable Home Inspections,
Inc.

|
Affordable Home
Inspection, Inc.
provides Professional Inspection services for Homes, Condominiums, Commercial
Real Estate, Swimming Pools, Spas, Mobil Homes and more. Please view our
"Items Inspected List to get a more detailed
version of what we inspect. "How much does it cost" you might ask?
- Please view our Fee Schedule list to see our current
prices.
- Our Professionals will inspect every aspect of your home, including:
exterior walls and roofs; windows, chimneys, driveways, sidewalks, patios,
fencing, sprinklers, swimming pools/spa and equipment, roof flashings,
gutters, and downspouts. Foundations (Underneath where applicable) venting,
sub flooring and access; electrical and plumbing systems. Garage door
hardware and springs, opener; garage electrical systems and slab. All
Interior Walls, ceilings, floors, doors, and windows; fireplace; closets.
Bathroom Sinks, plumbing systems, fixtures, mirrors. Kitchen and Laundry Room
Countertops, electrical and all appliances; vents and plumbing. Attic
Insulation, venting, ductwork, storage and structural systems; heating and
air conditioning systems.
- After the inspection is complete. You will receive a 14-16-page report that
is not only thorough, but easily understood. Included with the Buyer’s
copy is valuable Homeowner Information that will assist the new Homeowner for
years to come. Additional copies are provided as requested with no additional
charge.
SEE SAMPLE REPORT
GROUNDS
Grading- Visually inspected for possible conditions affecting
the structural integrity, and adverse water conditions, NOT including subsoil
conditions. In particular, we check for VISUAL evidence of settling and/or
improper grading that has resulted in structurally significant damage.
Driveway- Inspected for physical condition. Minor cracks must
reasonably be expected. Asphalt driveways require periodic resurfacing; such
routine maintenance items are not noted.
Walks- Inspected for physical conditions and possible hazards.
Patio- Patio and similar paving or decking and patio covers
inspected for physical condition and hazards.
Fences and Walls- Inspected for reasonable physical condition.
Lawns- Noted if they are badly neglected; not if they would be
improved by better care, weeding, etc…
Sprinklers: Inspected for proper installation and visual
evidence of flooding, not uniform or complete spray patterns (if on a timer,
and no manual bypass, we are unable to function test).
Landscaping- We report such conditions as tree limbs damaging
roofs; tree roots damaging paving, and similar faults.
POOLS AND SPAS
Pool and Spa- (if present) were inspected for reasonable
cleanliness of the water and for significant damage to the tile, coping, and
decking. We do not report minor cosmetic damage, expected shrinkage cracks,
in decks and plaster. Due to the reflective nature and distortion of water,
we are unable to judge the pool lining, unless the pool has been drained
Mechanical Equipment- Operated to verify that it runs without
leaking. Timer not checked beyond manual operation of switch. Heater operated
only if in service at the time of inspection; otherwise checked visually for
leaks only. Back flush valves are not tested. NOTE: all pools and spas
require regular maintenance, including filter servicing, chemical balancing,
water testing, and cleaning. These routine maintenance items are not included
in our service. .
Accessories- Accessories such as diving board, slide, pool sweep
device, are visually checked for physical condition. Pool sweeps are turned
on for an operational test. Cleaning efficiency is not judged.
Safety Features: Safety features are checked. These are two
safety enhancements which we recommend be added to any pool/spa. These are
not “faults” in the sense that retrofitting such devices are required by
code: Anti-vortex drain covers, which are much preferred to help prevent the
concentrated suction at the drains, which too often tragically result in
drowning. Ground fault interrupter (GFI) devices on pool and spa light
circuits reduce the risk of possible electrocution due to faulty light
circuits.
Low Voltage Lights- Low voltage lights are not tested.
EXTERIOR
House Walls- was inspected for water damage, settling damage
and similar non-cosmetic defects. Paint condition noted only if it is failing
to protect; not if repainting might be cosmetically desirable. Note that
minor shrinkage cracks in stucco are a cosmetic problem and not structurally
significant; thus are not reported.
Chimney- checked for possible settling damage and proper
flashing.
Foundation- visually checked for settling damage. Note that
houses of slab construction must reasonably be expected to have cracks,
sometimes hidden by carpeting or tile. This is normal and not reported unless
the cracks threaten the structural integrity of the house. On raised
foundation houses, vents are checked for adequacy and screening; accessible
portions checked for freedom from evidence of chronic water problems, and
integrity of visible wiring and plumbing.
Roof- was checked for estimated remaining life. When applied in
a workmanship manner, roofing industry standards claim the following life
expectancies for the following types of roofing materials - Rolled
Composition 4-6 yrs., composition shingles 12-15 yrs., built-up (rock,
gravel, etc) 10-15 yrs, wood shingle 18-20 yrs., medium shake 20-25 yrs.,
heavy shake 30-35 yrs., tile and slate 30-50 yrs., fibrous cement materials
30-50 yrs (South facing exposures will wear out faster)., faulty vents or
flashing; and possible threatening trees or shrubs are also checked. While
every effort is made, it is virtually impossible to determine if a roof is
leaking unless it is raining at the time of the inspection. Our opinion does
not constitute a warranty that the roof is, or will remain, free of water
intrusion. If a certification is desired, a licensed roofing contractor is
the person best qualified to provide this service. Due to their fragile
nature, we do not walk on tile or slate roofs.
Garage- checked for safety features, ventilation, if gas
appliances are installed there; and overall physical condition. Door opener,
if any, operationally tested (sensitivity of anti-reverse device is not
determined, remotes not tested). Door and wall to house, if any checked for
proper fire protection features. Wiring in garage checked for potential
hazards. Slab and foundation, checked for potential hazards . Slab and
foundation checked for visual settling damage.
Other Building- if any, and inspected, checked for physical
conditions.
UTiLITIES
Water- piping checked for leaks , presence of main shut-off
valve( not function tested), and if galvanized piping, for excessive pressure
drop (some drop is to be expected, especially when compared to an all copper
system).
Sewer systems and septic tanks systems- were not tested except to verify that
all fixtures drain at time of inspection. Ruptures or blockages can occur at
any time and without warning.
Electric service- visually checked. Main service panels are not
removed nor is ampacity calculated. Safety features checked include aluminum
wiring considerations (representative sample, not 100% check of all outlets)
and grounding. On houses that have ground fault interrupters, these devices
were tested for normal operation.
Gas service - visually checked. Each gas appliance that is in
service at the time of inspection (except dryers, barbecues, and fire-pits)
are operationally tested. Appliances are visually examined for significant
rust, damage, and similar deterioration. We do not pressure test lines,
slight gas leaks are often undetectable. WE recommend that you contact the
local gas company prior to the close of escrow to further evaluate gas
appliances and piping. This is provided as a free service.
Water Heater- checked for leaks, operation and strapping.
Furnace- checked for operation. Generally, heat exchangers are
not visible without dismantlement, therefore they are not within the scope of
our inspection. If they are a particular concern, we would recommend that the
gas company be consulted prior to the close of escrow. Thermostats and timers
are not checked beyond manual operation of switch. Uniformity and adequacy of
heat or cool air distribution is not judged. Purifiers and humidifiers are
not inspected. Ducting not inspected for hazardous materials.
Air Conditioning- Central air tested for normal operation
provided the outdoor temperature was over approximately 60 degrees F (testing
below that temperature is inconclusive). Adequacy is subjective and not
judged.
Laundry Facilities- checked for presence of a vent for the
dryer and provision of gas and/or 220 volt electricity. WE do not operate
washers & dryers, therefore a functional test of the vent, drain and
faucets is not possible.
Water Softener & Water Purification Systems - Not Tested.
INTERIOR
Entry- checked for damage to door, flooring, and similar features.
Walls & Ceilings- checked for water stains or damage, and
physical damage (but not behind existing pictures, paneling, wallpaper, etc.)
Minor cracking of plaster walls and slightly visible seams are considered
reasonably normal and not reported. When specified, wall installation is
checked for presence and material.
Flooring- checked for condition (unless covered by carpeting,
tile, linoleum,etc.)
Interior Doors- a sample was checked for physical condition and
possible evidence of settling.
Windows- Visual check for water penetration, evidence of
settling and overall physical condition; sample checked for broken panes
and/or torn screens. Efficiency of double pane glass is not judged. Broken
seals and vacuum may be present but not visible. Not a 100% check.
Sliding Glass Doors- checked for tempered glass (reported only
if the house is more recent than 1965, when the building code made tempered
glass mandatory), normal operation, and water damage. French doors are
checked for operation and water damage.
Fireplace- visually checked for freedom form excessive creosote
deposits within the flu ( a potential fire hazard). For a functioning damper,
for firebox or flue damage, and for evidence of smoking.
Stairways- checked for safety considerations and overall
condition.
Attic- checked for ventilation, vent screening and active leaks. Not
inspected for environmental hazards.
Wet Bars- Checked for normal operation and condition.
Balconies- checked for railings and satisfactory
decking.
KITCHEN
Range- checked for physical condition,
operation of heating elements ( and vent fan if so provided). Lights, timers,
and thermostats not checked. Oven thermostats are not precise devices, and
most manufacturers recommend a little experimenting, then adjusting cooking
habits to compensate. Built in microwave ovens are tested for operation
(presence of dedicated circuit is not determined)
Dishwasher- checked for physical condition, leaks and
operation. Washing efficiency is not judged.
Disposal- checked for condition, leaks and operation. Grinding
efficiency is not judged.
Sinks- checked for physical condition, and visible conditions
beneath the sink (water leaks, damage, etc.)
Cabinets and Counters- checked for reasonable condition, allowing for
normal wear and tear.
Electric outlets- are checked for proper operation and grounding
Flooring- is visually checked for condition, allowing for
normal wear and tear.
Lighting- is checked for normal operation.
Ventilation- is verified; either a window or by the kitchen
being open to an adjoining ventilated area.
Compactor- tested for normal operation. Compaction efficiency
is not judged.
Water Purifiers- are not tested.
BATHROOMS
Tubs and Showers- checked for physical condition of finish, wainscoting
material, and valves. The drainage is not checked and reported only if
clogged. Shower pans are not leaked tested. Overflow devices are not tested.
Lavatories- checked for physical condition of bowl and vanity
counter, faucets, and leaks beneath.
Toilets- checked for physical condition, operation and for
being solidly attached to the sewer flange at the floor. Cracks in porcelain
can occur at any time and without warning, therefore they should be
thoroughly checked at the time of the final walk through.
Electric Outlets- checked for normal operation and grounding.
Heat- tested if provided separately from the central heating
system.
Walls- checked for physical damage (but not behind wallpaper, paneling,
mirrors, tile, etc.).
Water Volume- checked in houses with galvanized plumbing for
volume drop.
|
Affordable Home Inspection, Inc.
follows the Fee Schedule below:
|
|
Houses &
Planned Unit Dev.
Price
0 to 1000 sq. ft.
$250.00
1001
to 1500 sq. ft.
$280.00
1501
to 2000 sq. ft.
$310.00
2001
to 2500 sq. ft.
$340.00
2501
to 3000 sq. ft.
$370.00
3001
to 3500 sq. ft.
$400.00
3501
to 4000 sq. ft.
$430.00
4001
to 4500 sq. ft.
$460.00
4501 to
5000 sq. ft.*
$490.00
Condos, Townhomes,
Manufactured Homes, & Mobile Homes
Up to 1500 sq. ft.
$250.00
Up to 2000 sq. ft.
$280.00
Up to 3000 sq. ft
$340.00
Up to 4000 sq. ft
$400.00
Up to 5000 sq. ft.*
$460.00
Pool and/or spa
(with inspection)
$50.00
Re-Inspection
60% of Fee
Single
System
$200.00
Additional Roof
$150.00
Duplex
$405.00
Triplex
$455.00
Fourplex
$505.00
Over 4 Units
Call For Quote : 800-946-7732
Escrow Billing
Service
Fee
$75.00
Trip Charges
for Outlying
Areas
Call For Quote : 800-946-7732
* Over 5000 Sq. Ft. = $30.00 per 500 Sq. Ft.
|
|
|
Prices subject to change without notice.